Ceramic tiles, Sanitary, Energy Drink, Soup, Fertilizers, Phosphate Products, Garlic, Water, Pasta, Sunflower Oil, Chicken, Sugar, Urea, Cocoa, Foodstuff, Pesticides, Concentred Brazilian Natural Juices.  Wheat, Corn/Maize, Cement, Clinker, Wheat, Rice, Soybean, Canned Tuna & Sardines, Coal, DAP, HMS 1&2, HMS 1, Milk Powder, Honey, Chemicals, Used Rails, Silica Sand, Beverages, Wood, Groundnuts, Seeds, Pulses,  Beer, Wine, PP Bags

ChemicalsFoodBeveragesAgricultureConstructionMetal & MineralOthersContact us

CEMENT

ORIGIN: INDONESIA - 4003001

 

 

 

 

 

 

PORTLAND CEMENT TYPE –1

 Chemical Composition

Characteristic

% By Weight

Requirement According to ASTM C-150-97

Requirement According to SNI 15-2094-94

Silicon Dioxide

SiO2

21.24

Limit Not Specified

Limit Not Specified

Alumunium Oxide

Al2O3

5.24

Limit Not Specified

Limit Not Specified

Ferric Oxide

Fe2O3

3.41

Limit Not Specified

Limit Not Specified

Calcium Oxide

CaO

64.62

Limit Not Specified

Limit Not Specified

Magnesium Oxide

MgO

1.38

Maximum 6.0

Maximum 6.0

Sulfur Trioxide

SO3

2.25

Maximum 3.0 when C3A is 8% or less

 

Maximum 3.5 when C3A is more than 8%

Maximum 3.0 when C3A is 8% or less

 

Maximum 3.5 when C3A is more than 8%

Sodium Oxide

Na2O

0.08

-

-

Potassium Oxide

KsO

0.30

-

-

Equivalent Alkalis as Na2O

0.28

Maximum 0.6 (optional requirement)

Maximum 0.6 (optional requirement)

Loss On Ignition

LOI

1.00

Maximum 3.0

Maximum 5.0

Insolube Residue

IR

0.40

Maximum 0.75

Maximum 3.0

Tricalsium Silicate

C3S

55.15

Limit Not Specified

Limit Not Specified

Dicalsium Silicate

C2S

19.29

Limit Not Specified

Limit Not Specified

Tricalsium Aluminates

C3A

8.12

Limit Not Specified

Limit Not Specified

Tetracalcium Aluminate

C4AF

10.38

Limit Not Specified

Limit Not Specified

 Physical Properties

Characteristic

Unit

Test Result

Requirement According to ASTM C-150-97

Requirement According to SNI 15-2094-94

Fineness Specific Sueface Blaines Air Permeability

M2/Kg

325

Maximum 280

Minimum 280

Autoclave Expansion

%

0.01

Maximum 0.8

Maximum 0.8

Compressive Strength

3 days

Kg/Cm2 (psi)

195 (2772)

Minimum 1740

Minimum 125

7 days

Kg/Cm2 (psi)

280 (3980)

Minimum 2760

Minimum 200

28 days

Kg/Cm2 (psi)

390 (5543)

Minimum 4060 (optional requirement)

Minimum 280 (optional requirement)

Time of Setting Vicat Test

Initial Set

Minutes

120

Minimum 45

Minimum 45

Final Set

Minutes

220

Maximum 375

Maximum 375

False Set Final Penetration

%

85

Minimum 50 (optional requirement)

Minimum 50 (optional requirement)

Air Content of Mortar

%

9

Maximum 12

 

Cement Compiles with Indonesian Standard SNI 15-2094-94 and ASTM C-150-97 for Portland Cement Type 1 and Equivalent Type according to Major International Standards

This Cement exhibits dark color

Above test result are typical value and not the binding specification